famet sa

PLENDERU


Gas filters


FAMET manufactures and delivers gas filters which are applied in natural gas booster stations located on gas pipelines. Gas filters are to remove mechanical and liquid impurities from the natural gas stream on suction side of turbo compressor.
  • service access to candle filter cartridges through bayonet closure with hydraulic quick opening system
  • during maintenance - inlet and outlet nozzles are blinded by hydraulic driven binocular blind flange systems
  • special outflow chamber decreasing flow resistance and noise level
  • rock wool (120 mm) insulation
  • possibility of build-in the complete set of measurement equipment (pressure, differential pressure, temperature, condensate level)
  • possibility of build-in safety-valves and blown down valves
  • electric tape heating of condensation
  • automatic draining away of condensate to a sump area
  • gas filters unit consists of five vertical filters with common service platform (four filters in operation, one stand-by)
  • service access to filters station from two-floor platforms with stairs is provided
REFERENCES :